Welcome To b2b168.com, Join Free | Sign In
中文(简体) |
中文(繁體) |
Francés |Español |Deutsch |Pусский |
| No.13642069

- Product Categories
- Friendly Links
- home > Supply > DLPL quantitative control system, quantitative control of water flow meter manufacturers, Guangdong quantitative increase in the production of water meter
DLPL quantitative control system, quantitative control of water flow meter manufacturers, Guangdong quantitative increase in the production of water meter
Information Name: | DLPL quantitative control system, quantitative control of water flow meter manufacturers, Guangdong quantitative increase in the production of water meter |
Published: | 2015-01-21 |
Validity: | 9930 |
Specifications: | DLPL quantitative control system, quantitative control of water flow meter manufacturers, Guangdong quantitative increase in the production of water meter |
Quantity: | 1.00 |
Price Description: | |
Detailed Product Description: | With the expansion of production scale, increase production, in order to improve production efficiency and reduce production costs, automatic quantitative control equipment will be used in many companies, or the need for reconstruction projects; 迪川 company actively respond to the needs of customers, developed a DLPL quantitative control system, which is simple to learn, intuitive display, manual or automatic control traffic flow control combined with other characteristics. Especially for oil mixed with oil, mixed with water, mixed with drugs, ingredients, quantitative and quantitative water control various liquids. Mainly for the present, some still using manual canned / play materials / ingredients / add water, but do not want to put too much cost, wanted to improve the efficiency of enterprise users, we recommend the use of the system. DLPL quantitative control system according to customer requirements, customize different dosing system. First, the system is composed of a flow sensor: This is the basis of control, directly affect the control of the results, so the basic requirement is the higher measurement accuracy is better, there is a signal output function. Meanwhile flowmeter type more, but also for selection according to the measured medium, pipe diameter, flow range, explosion, corrosion, protection class and other parameters and requirements, select the appropriate meter. 2, DLPL control box: includes quantitative control device, the internal control lines and components, such as external control buttons and lights, standard size box of 400 * 300 * 150mm, input power (AV220V) unified control box to power other devices such as flow sensors, solenoid valves and other equipment are powered directly inside the control box; and increase access printing. 3, drying equipment: the existing conduit may be power equipment, such as pumps; may also be larger block of solenoid valves, electric valves and other equipment. Second, quantitative control process control instrument after receiving traffic signal meter in its interior complete cumulative flow, while the value of a good set of quantitative control required in internal control device, when the accumulated value of quantitative control instrument display reaches the set The quantitative control value, quantitative controller output switch signal. At this signal by using this switch is connected with the relay or contactor to control shut-off device is installed in the pipe, so as to achieve the effect of quantitative control. ? Third, the product features 1, only flowmeters, control boxes and drying equipment components, simple structure, low cost; 2, the control box of the control circuit and components are based on the meter and the equipment customers need to tailor The signal line connection is simple, the flowmeter and drying equipment powered directly from the control box inside, usually without adjustment to the scene;? 3, the control device for the whole Chinese display, easy operation, visual display; control box panel has a "start" "stop" and "reset" button, but also external button, and a "status indicator" shows, so intuitive display, simple operation, convenient, easy to learn;? 4, each value can be any quantitative control required changes, just the operation is completed within the quantitative control device, can also be set in accordance with the requirements of the usual dose groups, direct selection on the line, no need to set it again when playing material; Fourth, the main function of a, with large and small valve control, are controlled high flow and low flow, to achieve accurate quantitative control; 2, while the control of pumps and valves, has a pump delay start function off valve and the pump in advance; 3, with a flash, hold the pump interface, the occurrence of flash, hold pump off when playing material immediate protection;? 4, in the quantitative control device can view the total cumulative flow rate, time, flow meter input signal values, etc., and a number of hit material, each feeding time to play, you play material amount, date or month cumulative etc. inquiry; 5, can be equipped with a printer to print real-time capabilities, printing capabilities, including the starting and ending time to play material, playing quantity, quantity actual playing, playing material name (according to customer requirements set free); break Power remains active material before the fight. 6, the control device and the control box is completely independent research and development, so that we can make other features For customized; V. Ordering Information 1. Select the appropriate meter: Measuring media name advertised, measuring tube diameter, operating pressure and temperature, flow range or other requirements, we give you the selection; 2, indicating control requirements: such quantitative values ??for each size, the number of daily control, the value is the same for each control and other requirements; 3, select the drying equipment: as has been drying equipment please let its operating power and power, we make tailored; if necessary we can also provide drying equipment. Here we recommend drying device, select the solenoid valve or electric valve (a delay in startup or shutdown) is better, do not control the pump, while at the piping to the stagnation level difference generated by the power source for the best , so that when the control most secure, but also the best measurement accuracy. Sixth, on-site installation and piping diagram of an installation considerations. Meter installation (see instructions): At least guarantee before the meter before and after a straight pipe after 10D 5D (D is pipe diameter), and the longer the better, as far as possible in front of the pump and want to increase the regulating valve straight pipe before length away from them, near the mount point should be no strong electric, magnetic and frequency interference. Installation point pipeline must be full pipe flow when the pipe is installed vertically oriented, fluid must flow from bottom up. 2. Solenoid valve: meter should be installed in the rear, and with the meter should 10D (D is pipe diameter) over a distance, to avoid vibration and electromagnetic solenoid valves before and after the operation due to the impact of measurement accuracy of the meter, in addition to the solenoid valve mounting point should be as close exit flow is appropriate. 3. Control Box: Non-waterproof, it is recommended to install in the room; if installed outdoors or order shall require the use of waterproofing waterproof control box. Quantitative measurement principle ?? beginning when the flow control device indicating quantitative electromagnetic valve is open, fluid enters the flow sensor. When the flow sensor signal to the flow control device and start the quantitative measurement, the flow reaches the set value, quantitative Totalizer control device instructs the solenoid valve off, back to the original closed state.迪川 flow sensor and solenoid valve according to the site to select the desired flow rate and pipe press figure connected with the quantitative control instrument quantitative control instrument's display as shown, standard size box of 400 * 300 * 150mm (H * W * thick) of the pulse (current) flow sensor output calculation formula Q = N / K where? Q -------- cumulative flow (in liters) ??? N -------- traffic signal number of pulses (pulse number corresponding current (times) ??? K- ------ instrument constant (Ci / l) ?? placed within the meter constant control device, the control device according to the setting value is automatically calculated ), initiate recovery of the relay control device when the built-in relay state changes, so that the control valve is opened, the control device of the pulses from the sensor (current) signals are counted, the amount of the original reaches the set state, the control valve will close, in order to achieve Quantitative pipe flow (batch) control. ■ Technical parameters measuring medium: liquid or gas. Quantitative range: 0.1-999999 liter can be placed in the instrument constant max: 999999 times / upgraded sensors provide: 12VDC, 50mA Power Environmental conditions: 0-45 ℃, relative humidity <85% Power: AC220V 11-bit display cumulative total 4 bit display instantaneous value. Dimensions:? 160 * 80 * ?? cumulative total, instrument constant and the quantitative value of the previous power-down protection, the protection of longer than 10 years. The warranty period is 12 months. ■ quantitative process control ?? to jar with water (eg 60L), enter the quantitative value 60L in Flow Totalizer (quantitative control device), and then press the start button (or the Enter key), flow totalizer relay is closed (electromagnetic valve is opened, water lights), flow totalizer began to accumulate, when the cumulative number upon arrival 60L, flow totalizer disconnect relay (solenoid valve closed, water lights off), this quantification is completed. If you want the next quantitative control, adjustment shall be cleared at the button, then the above steps, such as the need to pause in the middle, press the stop button, if the quantitative value is consistent with the previous press start button. ■ control requirements ?? controller for 4-20mA input or pulse signal with an external start, stop, clear, two relay outputs. Relay to the solenoid valve to be added an intermediate relay, if the solenoid valve is a 24V power supply, the need to increase a 24V switching power supply. ?? Note: The lights, buttons, relays, air switch, AC contactor (can be saved), quantitative control device (LCD), control box, consisting of a control system, control site (24VDC) solenoid valve to start or stop, Another to add a total power switch, flow meter, solenoid valves, according to site requirements need to do. (Accessories can match the user's own)? ■ Ordering a measuring media name, measuring tube diameter, operating pressure and temperature, flow range or other requirements. 2, control requirements: As the size of each assay value, the control of the number of times a day, each time the control value is the same, and other requirements. 3. Select the drying equipment: If the device has been drying up, please announce its operating power and power, we make tailored; if we need to provide shut-off device can also be quantified Nanning flow control, Guangxi quantitative flow control, ingredients? quantitative control of water control systems Guangdong Guangzhou quantitative dosing system overview XSJDL series of quantitative flow control device with various sensors, transmitters cooperate to achieve quantitative canned ingredients control. ▲ error is less than 0.2% FS, and have adjusted, digital filtering, can help reduce the error sensors, transmitters, and effectively improve the measurement and control accuracy ▲ applies to current, voltage, pulse output flow sensor ▲ 3 point switch inputs for start, recovery, and each time the accumulated value is cleared ▲ 3-point control output for large valves, small valves hierarchical control and instantaneous flow ▲ lower alarm transmitter output can be instantaneous flow value standard current The voltage output in the form, for other devices ▲ 8 segment polyline computing capabilities can reduce the flow sensor nonlinearity error ▲ instantaneous flow rate by the hour or by the minute as the unit of measurement to select ▲ fully transparent, high-speed, efficient network communication interface, Computer and complete data transfer between instruments and control. Exclusive control over the transfer function so that the computer can directly control the instrument working status and transmission output. Read a measurement time of less than 10ms to provide data to test software, configuration software and application software support ▲ with printing interface and printing unit with hardware clock for manual, time, alarm printing capabilities. If the optional smart printing unit, enabling more than one instrument share a printer basic technical specifications ▲ power ??? Source: 220V AC powered instruments: 220V ± 10%, power consumption is less than 7VA; 24V DC powered instruments: 24V ± 10%, power consumption is less than 5VA; 12V DC powered instruments: 9V ~ 20V, power consumption is less than 5VA Other Power Specifications subject to random manual ▲ work environment: 0 ℃ ~ 50 ℃, humidity below 90% RH. Wide temperature range of the instrument required when ordering ▲ show significant ???: double: first row 8, green, switch displays the total cumulative amount of instantaneous flow rate and current quantitative values ????? ?????? ???????? second row of six red, showing the cumulative amount of each input signal ▲: DC Current: 4mA ~ 20mA, 0mA ~ 10mA, 0mA ~ 20mA can be selected by setting ?????? ?????? DC voltage: 1V ~ 5V DC, 0V ~ 5V DC can be selected by setting ???????????? Pulse: 0.1Hz ~ 10KHz ▲ Input impedance: mV input meter is greater than 10MΩ V input meter 230k mA input meter 46Ω ▲ basic error: less than ± 0.2% FS ▲ measurement and control cycle: 0.2 seconds ▲ switch input: passive mechanical switch ▲ control output: relay contact capacity 220V AC, 3A |
Admin>>>
You are the 18224 visitor
Copyright © GuangDong ICP No. 10089450, Guangdong meter factory All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility
You are the 18224 visitor
Copyright © GuangDong ICP No. 10089450, Guangdong meter factory All rights reserved.
Technical support: ShenZhen AllWays Technology Development Co., Ltd.
AllSources Network's Disclaimer: The legitimacy of the enterprise information does not undertake any guarantee responsibility